HCS-D User Manual
SPECIFICATIONS
Line Input Power
Voltage & Wiring:
Supplied Input
Conductors:
Voltage Range:
Frequency:
CCID:
Current & Output
Power: (at 240V AC)
Plugs:
Dimensions:
Weight:
Environment:
Agency Approvals:
240V AC single-phase - L1, L2, and Safety Ground.
208V AC 3-phase wye-connected - Any two phases and
Safety Ground.
240V AC 3-phase, delta-connected. With center-tap on
one leg, must use only the two phases on either side of
the center-tap. The two phases must both measure 120V
AC to ground. Do not use the third leg (208V "Stinger").
Pre-installed supplied input conductors of the HCS-D40,
HCS-D40R, and HCS-D50: L1, L2 and Ground use 3 feet of
8AWG, 90ºC copper wire.
185V AC to 264V AC
60 Hz
20mA
HCS-D Model
Number
HCS-D40R (hardwired) 40A
HCS-D40R (hardwired) 40A
HCS-D40PR+ 14-50P 40A
HCS-D50 R (hardwired) 50A
HCS-D50PR+14-50P 50A
NOTE: that the maximum current for the vehicle is set by the duty cycle of
the Pilot waveform. Output power is variable depending upon
the HCS-D model and vehicle demand.
An attached NEMA 6-50P or NEMA 14-50P plug is
available on the HCS-D40PR and HCS-D50PR.
A 14-50R or 6-50R receptacle is also supplied and must be used
with your plug type EVSE product.
Dimensions are for the enclosure only:
Height:
500 mm
Width:
225 mm
Depth:
135 mm
HCS-D conduit with two 40A SAE J1772 connectors and
25' lengths of cable: 9.5 kg (21 lbs)
HCS-D plug with two 40A SAE J1772 connectors and 25'
lengths of cable: 9.5 kg (21 lbs)
Ruggedized HCS-D40 plug with two 32A SAE J1772
connectors and 25' lengths of cable: 9.5 kg (21 lbs)
Operating Temperature: -30°C to +50°C (-22°F to +122°F)
Storage Temperature:
Enclosure Rating:
ETL Listed, FCC Part 15 Class B, ENERGY STAR
32
Circuit
Max
Breaker
Current
32A
32A
32A
40A
40A
(19.7 inches)
( 8.9 inches)
( 5.3 inches)
-40°C to +80°C (-40°F to +176°F)
NEMA 4 - watertight
Output
Cable
Power
Length
7.7 kW
18 ft (5.49m)
7.7 kW
25 ft (7.6m)
7.7 kW
25 ft (7.6m)
9.6 kW
25 ft (7.6m)
9.6 kW
25 ft (7.6m)
Certified
®