3.2.4 Continuity
Range
Built-in buzzer will sound, if resistance is lower than 50Ω
- Open circuit voltage: approx. 0.5V
- Overload Protection: 250V DC or rms AC
3.2.5 Diode
Range
Resolution
0,001V
- Forward DC Current: approx. 1mA
- Reversed DC Voltage: approx.1.5V
- Overload Protection: 250V DC or rms AC
3.2.6 AC Voltage Detect
Range
Sensitivity
Frequency
Distance
- Non-contact detecting
4.
OPERATING INSTRUCTION
4.1 Data hold
If you need data hold when measuring, you can put on "DATA-H" button, it will
hold the reading; if you put the button again, data hold is not continue.
4.2 Maximum value measuring and holds
At the range of voltage, you can put on "MAX.H" button, it will hold the maxi-
mum value; if you put the button again, the maximum value will not be held.
4.3 Function transform
Put down the "FUNC." when measuring the voltage. Meter will be transformed
between DC and AC range. Put "FUNC." when measuring the resistance, di-
KPS-MT20L • Non-contact voltage detector
Function
Display: read approximate forward
Voltage sensitivity >50V, adjust continuously
< 150mm ( change along with the sensitivity)
24
Function
voltage of diode
TEST
50Hz