Appx. 1 Estimating Operation Time
To estimate the operation time of the AC70P, consider the load you're applying:
•
For high-power loads (above 300W):
Operation time = Battery Capacity (Wh) x DoD x η ÷ Load Power
•
For small-power loads (below 300W):
Operation time = Battery Capacity (Wh) x DoD x η ÷ (Load Power + Self-consumption of
AC70P)
Note: DoD refers to depth of discharge. AC70P works at 90% DoD for longer battery life.
η is the conversion efficiency of the inverter, typically over 85% for AC70P.
The self-consumption of AC70P is approximately 15W.
E.g. If you have a 40W refrigerator, you can run it for about 12 hours.
Operation time = 864Wh × 90% × 85% ÷ (40W + 15W) ≈ 12 hours.
Please keep in mind that the estimated operation time provided is for only purposes and
may vary based on actual usage conditions. Factors such as low temperature and
excessive loads can significantly affect the battery capacity, leading to a reduction in the
average operation time.