SunPower Maxeon 3 104 cells Residen al Solar Panel
(SPR-MAX3-XXX, SPR-MAX3-XXX-BLK)
0
150
50
254
TOP CLAMPS
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
Long Side Moun ng,
Rails Parallel to
Moun ng Frame
Short Side Moun ng,
Rails Perpendicular to
Moun ng Frame
(End Mount)
Short Side Moun ng,
Point Supported
(End Mount)
Short Side Moun ng,
Rails Parallel to
Moun ng Frame
(End Mount)
1 In the cases where hybrid moun ng is necessary (combina on of long and short side moun ng), the lowest
design load values should be considered as allowable design load.
2 Test loads are for informa on purposes only, design loads should be considered for the project design.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
par es, unless there is a formal authoriza on by Maxeon.
©2024 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Safety and Installation Instructions - Document 001-15497 Rev.AB
423
646
1100 mm
1300 mm
1500 mm
1690 mm
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
A - Ground Holes (4X Ø4.2mm)
B - Moun ng Holes (8X Ø6.8mm)
Moun ng Zone
Test Load
Design Load
Loca ons
Downward/Upward
(distance from corner
Downward/Upward
(Pa)
(Pa)
in mm)
50 - 150
+2700/-2700
+1800/-1800
150 - 254
+2400/-2400
+3600/-3600
254 - 423
+8100/-5400
+5400/-3600
+3600/-3600
423 - 646
+2400/-2400
50 - 150
+2700/-2700
+1800/-1800
150 - 254
+3600/-3600
+2400/-2400
254 - 423
+5400/-5400
+3600/-3600
423 - 646
+3600/-3600
+2400/-2400
50 - 150
+2700/-2700
+1800/-1800
+2400/-2400
150 - 254
+3600/-3600
254 - 423
+3600/-3600
+5400/-5400
423 - 646
+3600/-3600
+2400/-2400
BOLTS
0 - 350
+2700/-2700
+1800/-1800
0 - 350
+2700/-2700
+1800/-1800
0 - 350
+2700/-2700
+1800/-1800
MAXEON SOLAR TECHNOLOGIES, LTD.
423
646
GEN 4.2 FRAME PROFILE
SIDE FRAME PROFILE
32 mm
Moun ng
Moun ng Configura on Diagram
Configura on
Descrip on
Front View
Back View
Long Side Moun ng,
Rails Perpendincular
to Moun ng Frame
Long Side Moun ng,
Point Supported
4 Rails must not be under the junc on box.
6 Bo om Flange Moun ng.
7 Range indicates posi oning of the clamp and not the rails.
8 Slight bending may occur due to weight of the module.
0
150
50
254
B
A
END FRAME PROFILE
24 mm
Moun ng Zone
Test Load
Design Load
Loca ons
(distance from corner
Downward/Upward
Downward/Upward
(Pa)
(Pa)
in mm)
1300mm Holes
+8100/-3600
+5400/-2400
1100mm Holes
+8100/-3600
+5400/-2400
1300mm Holes
+5400/-3600
+3600/-2400
1100mm Holes
+5400/-3600
+3600/-2400
EN