Voltage - AC/DC
1. Press
to turn on the instrument
~
2. The meter defaults to VAC (V).
• To select VDC (V), press
once.
3. Insert test leads into the corresponding input terminals.
4. Connect the leads to the circuit under test. The voltage value is
displayed.
Red
Black
5
Resistance (Ω)/Continuity
1.
Turn on the instrument.
two times to select Ω/
2. Press
3. Insert test leads into the corresponding input terminals.
4. Apply test leads to de-energized circuit and press
the measurement.
5. Apply test leads:
• The ohms value is displayed.
• If <30Ω, continuity beeper also sounds.
P
Note: Press
LOCK
N
mode. LOCK is displayed and APO is defeated.
PE
R
R
E
T
For higher accuracy and resolution:
• Press
to select LoΩ (0.00 - 19.99Ω).
• Null (ZERO) test leads by touching test lead tips tightly together.
Press
>2 sec. The resistance of the leads is now subtracted from
ZERO
pending measurements until
• Repeat steps 3 - 5 to take resistance measurements.
)
)
)
) .
)
)
to perform
TEST
and
TEST
to perform measurements in continuous
BOILER
Red
Black
ZERO
is pressed again.
6
R
E

Publicidad