Velleman CU2200 Manual Del Usuario página 11

Sistema de alarma inalámbrico por mensajes sms
Ocultar thumbs Ver también para CU2200:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

• Operating Voltage Low Level Alarm Message
When the power supply voltage level is below the minimum level at 5.34VDC, the CU2200 will send an alarm
SMS message.
Date
2007-06-15
Time
13:25
ST:001;TM200706121325;V:5.34#
• Operating Voltage Low Level Alarm
This command is used to set the action to be taken once the operating voltage drops below 7.0VDC. Value of
the current operating voltage can be retrieved by command 2.
Command: PWD:XXXX,ADCOUT0:YY,ZZZZ,NNN%
XXXX
Password
YY
00 means alarm not reported to control centre
10 means alarm reported to control centre 1
01 means alarm reported to control centre 2
11 means alarm reported to control centre 1 and 2
ZZZZ
Selection of the alarm phone dial and alarm SMS
0 means no alarm report
1 means SMS only
2 means phone dial only
3 means SMS first, then phone dial
ZZZZ
4
3
rd
2
nd
1
phone number
st
NNN
Relay output control
0 means no relay output control
1 means relay output triggered by alarm
NNN
3
rd
2
nd
1
relay output
st
• Arm/Disarm Setup
Command: PWD:XXXX,ARM%
XXXX
Password
CU2200_v4
phone number
th
phone number
phone number
relay output (not available)
relay output (not available)
11
VELLEMAN

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido