XXXXXXXXXX Alarm report phone number
Y
Alarm report enabled/disabled
XH:XX
GSM network signal strength (1 ~ 31)
Command: PWD:XXXX,PARAMETER2%
About the alarm channel
[SMS message received]
ST:XXX;VL:XXXXX,O:AX,BBBB,CCC:A1M:XXXXX,XXXXX,R,WWWWW,WWWWW,O:AX,BBBB,CCC;A2M:X
XXXX,XXXXX,R,WWWWW,WWWWW,O:AX,BBBB,CCC;K1:N,O:AX,BBBB,CCC;#
VL
Min. operating voltage (7VDC by default), alarm will be triggered if voltage drops below this level
A
Alarm report to control centre 1
0 means no report
1 means report
X
Alarm report to control centre 2
0 means no report
1 means report
BBBB
Report status for 4 phone numbers
0 means no report
1 means SMS but no phone dial
2 means phone dial but no SMS
3 means SMS first and then phone dial
CCC
Relay output control
0 means control not triggered by alarm
1 means alarm triggered control
K1:N,O:AX,BBBB,CCC refer to the alarm 1 status (see below)
Command: PWD:XXXX,PARAMETER3%
About the alarm 2 ~ 8 status
[SMS message received]
ST:XXX;K2:N,O:AX,BBBB,CCC;K3:N,O:AX,BBBB,CCC;K4:N,O:AX,BBBB,CCC;K5:N,O:AX,BBBB,CCC;K6:N,
O:AX,BBBB,CCC;K7:N,O:AX,BBBB,CCC;K8:N,O:AX,BBBB,CCC;#
K2
Alarm channel 2
N
0 means disabled
1 means closed triggered alarm
2 means open triggered alarm
3 means both closed and open triggered alarm
O
Corresponding output relay status
A
Alarm report to control centre 1
0 means no report
1 means report
X
Alarm report to control centre 2
0 means no report
1 means report
BBBB
Report status for 4 phone numbers
0 means no report
1 means SMS but no phone dial
2 means phone dial but no SMS
3 means SMS first and then phone dial
CCC
Relay output control
0 means control not triggered by alarm
1 means alarm triggered control