Descargar Imprimir esta página

PERMASTEEL PG-40301-BK Guía De Uso Y Cuidado página 23

Parrilla de gas de 3 quemadores

Publicidad

Idiomas disponibles

Idiomas disponibles

LP TANK VALVE USED MUST MEET THE FOLLOWING
1.
Have a type I outlet compatible with the regulator provided.
2. Have a safety relief valve.
3. UL listed Overfill Protection Device (OPD), This OPD safety feature is identified by a
unique triangular hand wheel. Only use LP tanks equipped with this type of valve.
CONNECT THE REGULATOR TO THE LP TANK
VERY IMPORTANT:
-
THE REGULATOR SHOULD NOT BE IN A LOCATION THAT WILL ATTAIN A
TEMPERATURE ABOVE 125ºF (51ºC).
-
THE REGULATOR SHOULD INCORPORATE A PRESSURE RELIEF VALVE OR
OVERPRESSURE DEVICE.
-
THE INLET OF THE PRESSURE REGULATOR SHOULD BE FITTED TO CONNECT THE
TYPE I CONNECTION OF THE TANK VALVE PER ANSIZ21.81.
1.
Make sure the tank valve is completely shut off (turn clockwise to stop).
2. Check the tank valve to ensure that it has the proper external male threads
(type I connection per ANSIZ21.81).
3. Make sure all burner knobs are in the off position.
4. Remove the protective cap from the LP tank valve. Always use the cap and strap
supplied with the valve.
5. Inspect the valve connection port and regulator assembly. Look for any damage or
debris and remove any debris. Inspect the hose for damage. Never attempt to use a
damaged or plugged equipment. Contact your local LP gas dealer for any repairs.
6. When connecting the regulator assembly to the valve, hand tighten the nut
clockwise until it is fully tightened. Do not use a wrench to tighten. Use of a wrench
may damage the quick coupling nut and can result in a hazardous condition.
7. Open the tank valve fully (counter-clockwise). Use a soapy water solution to check all
connections for leaks before attempting to light the grill. If a leak is found, turn the
tank valve off and do not use the grill until a local L.P gas dealer can make repairs.