Descargar Imprimir esta página

FISCHER FXC 85 Manual De Instrucciones Original página 23

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 65
Select nails suited to the intended application
Type
Item
DFN 17 NP
567321
DFN 20 NP
567322
DFN 22 NP
567323
DFN 25 NP
567324
DFN 30 NP
567325
DFN 35 NP
567326
DFN 40 NP
567327
DFNH 15 NP
567328
DFNH 17 NP
567329
DFNH 22 NP
567330
DFNH 27 NP
567331
DFNH 32 NP
567332
Filling the Magazine
· If necessary, clean the magazine slider (14) and maga-
zine (12), e.g. with a paintbrush.
· Push the nail slider (14) towards the magazine open-
ing until it engages.
· Push a suitable nail strip (21) into the magazine
opening. The standard magazine can be filled with
maximum 2 nail strips and the extended magazine
(accessory) can be filled with 4.
· Press the button (15) on the nail pusher (14) and slide it
forwards as far as it will go.
Note: If only 2 nails are contained in the magazine (12),
the contact element (17) can no longer be pressed
and no discharging procedure is triggered. Fill up the
magazine.
Emptying the Magazine
· Press the button (15) on the magazine slider (14)
and slide it towards the magazine opening until it
engages.
· Rotate the magazine so that the nail strip (21) can
slide out of the magazine opening.
Removing/Changing the Contact Element
(see figure C)
The contact element (17) can be removed to be cleaned
or changed.
Remove the rechargeable battery (10). Empty the maga-
zine (12) and remove it.
Pull the contact element release button (16) and remove
the contact element (17) from the power tool.
Push the cleaned or new contact element (17) into the
power tool until it engages.
MOAL_FXC-85.indb 23
MOAL_FXC-85.indb 23
Suitable for Length (mm) Diameter (mm)
Shank
Concrete
17
2.6
< C30/37
20
Sand lime
22
brick and
25
solid brick
30
35
40
Concrete ≥
15
3.0
C30/37 and
17
Steel
22
27
32
Material
Head
6.5
High-carbon
steel, galva-
nised
Operation
Starting Operation
Switching On and Off
To switch on the power tool, press the on/off button (1)
on the user interface until the user interface lights up.
To switch off the power tool, press the on/off button (1)
again.
The power tool switches off automatically after 30 min if
it is not being used.
Checking the Suitability of the Substrate
· Check the suitability of the substrate before loading
the power tool with nails or performing fastening.
The substrate must be level and free from residue.
To check the hardness of the substrate material, use
a nail as a centre punch. Use a hammer to hit it with a
powerful strike on the material. Check the result:
· The point of the nail is blunted: The substrate is too
hard and not suitable; the nail may ricochet.
· The material tears or splinters: The substrate is too
brittle and is not suitable. Particles may hit you or
other people, or the nail may completely penetrate
the substrate.
· When struck with a hammer, the nail sinks into the
substrate: The substrate is too soft and is not suitable;
the nail may fully penetrate the substrate.
· The nail leaves behind a small recess in the substrate:
The substrate is suitable for fastening.
Initiating the Discharging Procedure
· Switch on the power tool.
Nail strip
colour
Grey
EN
Black
23
13.07.2023 11:23:46
13.07.2023 11:23:46

Publicidad

loading

Este manual también es adecuado para: