c
min
· Please find the following information of fischer nails at
http://www.fischer-international.com:
· Nail head distance h
· Effective embedment length h
· Minimum thickness of concrete element h
· Minimum distance between two nails s
· Minimum edge distance c
· Recommended loads
Adjusting the setting depth
Set the fastening depth using the depth adjustment
switch (19) so that the correct value for the nail head
distance h
is achieved.
NHS
Nail too deep: Press the depth adjustment
switch (19) to the right.
If the nails are driven in too deep, use
longer nails.
Nail not deep enough: Press the depth
adjustment switch (19) to the left.
If the nails are not driven in deep enough,
use shorter nails.
Clearing Jams/Resetting
· Clear jams if the status display (2) lights up red or
orange, or if the nails are no longer discharged
correctly.
· Remove the rechargeable battery (10). Empty the
magazine (12) and remove it. Remove the contact
element (17).
· Check the magazine (12) and clear away dirt, residue
and foreign objects.
· Check the contact element (17) and clear away nails,
nail fragments, residue or foreign objects with the
punch pin (20). When doing so, ensure that you do not
damage the contact element.
· In sequence, re-insert the contact element (17),
magazine (12) and battery (10).
MOAL_FXC-85.indb 25
MOAL_FXC-85.indb 25
s
min
NHS
ef
min
min
· Switch on the power tool.
· Press the reset button (4) for 5 seconds.
· Press the contact element (17) against a wooden
block or similar and press the trigger (6). By doing
this, the motor can bring the firing piston into the
correct position.
· If another fault is detected, the power tool does not
return to normal operation. Instead, the other fault
appears in the status display (2).
Removing the Supporting Leg
· The supporting leg (13) allows the power tool to
be aligned at a perpendicular angle on an even
substrate.
· For work on an uneven substrate, you can remove
the supporting leg (13). To do so, slide it under the
magazine (12).
Hanging Up the Power Tool
· You can use the utility hook (22) to attach the
switched-off power tool to a suitable suspension
device.
Using the screw supplied, screw the utility hook (22)
to the housing of the power tool (see figure E).
· Check the utility hook (22) for damage or deformation.
· Do not use the utility hook (22) if it is damaged, de-
formed or no longer firmly secured to the power tool.
· Use the utility hook (22) to attach the power tool to a
suspension device.
· To avoid damage or injury, the suspension device
must not be attached above walkways or immediate
work areas.
· The utility hook is intended solely for the purpose of
hanging the power tool, including fitted accessories.
· Never use the utility hook as a fall protection system.
Transport
For transport, switch off the power tool; especially
when using ladders or moving in an unusual stance or
posture. Lock the trigger with the unlocking switch (5). At
the workplace, carry the power tool only by the handle (7)
and with the trigger (6) released.
User interface
The user interface is used as follows:
· For switching the power tool on/off
· As the power tool status indicator
· As the battery charge indicator
· For resetting