Status indicators
Colour of
Meaning/cause
the status
indicator
Green
The power tool is ready for use.
Yellow
Overheat protection: Motor or
EN
electronics are too warm.
Blue
Protection against cold: The
power tool is too cold.
Red
Jam detected: The firing pin
cannot return to the correct
position.
Orange
The motor is blocked: The firing
pin cannot be moved into the
correct position.
Cyan
Overcurrent protection: The motor
is consuming too much power.
Magenta
Maintenance is recommended:
(3 s long,
Error rate too high (e.g. bent nails
green
or inadequate penetration depth)
thereafter)
White
Electronics- or sensor fault
Battery charge indicator (3)
5× continuous green light
4× continuous green light
3× continuous green light
2× continuous green light
1× continuous green light
1× flashing green light
26
MOAL_FXC-85.indb 26
MOAL_FXC-85.indb 26
Solution
-
Allow the power tool to cool down. If the motor and electronics are within
the operating temperature, the power tool automatically returns to normal
operation.
Allow the power tool to reach the correct temperature in a warm
environment. If the motor and electronics are within the operating
temperature, the power tool automatically returns to normal operation.
Clear the jam (see "Clearing Jams/Resetting", page 25).
Clear the jam (see "Clearing Jams/Resetting", page 25).
Check the power tool for jams or significant contamination and clear these
(see "Clearing Jams/Resetting", page 25). If the error persists, contact an
authorised after-sales service centre for fischer power tools.
Contact an authorised after-sales service centre for fischer power tools.
The power tool has been put into safe mode and cannot be used. Contact an
authorised after-sales service centre for fischer power tools.
Maintenance and Service
Capacity
Remove the battery from the power tool before
80–100 %
carrying out work on the power tool (e.g. maintenance,
60–80 %
changing tool, etc.). The battery should also be
40–60 %
removed for transport and storage. There is risk of
injury from unintentionally pressing the on/off switch.
20–40 %
To ensure safe and efficient operation, always keep
5–20 %
the power tool and the ventilation slots clean.
0–5 %
13.07.2023 11:23:46
13.07.2023 11:23:46