• To replace the damaged mains cable, use
the cable type: H05V2V2-F which
withstands a temperature of 90 °C or
higher. A single wire must have a minimal
cross section in accordance with the table
below. Speak to your local Service Centre.
The connection cable may only be
replaced by a qualified electrician.
WARNING!
All electrical connections must be made
by a qualified electrician.
CAUTION!
Connections via contact plugs are
forbidden.
CAUTION!
Do not drill or solder the wire ends. It is
forbidden.
CAUTION!
Do not connect the cable without cable
end sleeve.
220-240 V~
N
N
L1
L2
220 - 240 V~
5x1,5 mm²
Green - yellow
N
Blue and blue
L1
Black
L2
Brown
3.4 Assembly
If you install the hob under a hood, please
see the installation instructions of the hood
for the minimum distance between the
appliances.
400V2N~
N
L1
L2
Two-phase connection: 400 V2N~
5x1,5 mm² or 4x2,5 mm²
Green - yellow
N
Blue and blue
L1
Black
L2
Brown
One-phase connection
1. Remove the cable end sleeve from black,
brown and blue wires.
2. Remove a part of the insulation of the
brown, black and blue cable ends.
3. Connect the ends of black and brown
cables.
4. Apply a new wire end sleeve on the
shared wire's end (special tool required).
5. Connect the ends of two blue cables.
6. Apply a new wire end sleeve on the
shared wire's end (special tool required).
Two-phase connection
1. Remove the cable end sleeve from blue
wires.
2. Remove a part of the insulation of the
blue cable ends.
3. Connect the ends of two blue cables.
4. Apply a new end wire sleeve on the
shared wire's end (special tool required).
N
L
One-phase connection: 220
- 240 V~
5x1,5 mm² or 3x4 mm²
N
L
220-240 V~
Green - yellow
Blue and blue
Black and brown
ENGLISH
57