Use of gas :
Rules to follow:
Use propane or butane only.
-The parasol heater is designed to be used with an 11-13 kg cylinder.
-The maximum size of the cylinder suitable for this appliance, with the regulator attached, is Ø31cm x 64cm. The
inside dimension of the foot that is in the support bar is Ø32cm x 69cm.
-The hose must comply with EN164361: 2014. Do not pull or twist the hose.
The connection to the appliance must be made with a supply hose of length 1.2m or 1.5m (maximum).
-Make sure that the hose is not subjected to any twisting or pulling forces
-The maximum inlet pressure of the pressure regulator must not exceed 100 PSI (690 kPa).
-The outlet pressure of the pressure regulator must be 28 mbar.
-The assembly of the hose and the pressure regulator must comply with the applicable standards. Ensure that
the regulator seal is correctly installed and capable of performing its function.
-The installation must comply with the applicable standards or, in the absence of standards, with the law on the
storage and use of propane and other liquid fuels.
-A dented, rusted or damaged gas cylinder can be dangerous and should be checked by your gas supplier before
use. Never use a gas cylinder with a damaged connection valve.
-The gas cylinder must be installed upright.
-Avoid twisting the hoses and pipes.
-Never connect a gas bottle that is not certified or not suitable for the appliance.
-Disconnect the gas bottle when the appliance is not in use.
Leakage test :
The appliance connections were leak tested before leaving the factory.
A complete check of the strength of the connections must be carried out during installation.
Do not use the heater until the leakage test has been carried out on each connection.
The entire gas system, hose, regulator and burner must be leak tested before use.
Check the hose assembly for extreme abrasion, cuts or tears. If in doubt, perform a leak test. If the hose is
leaking, it must be replaced with a new hose that complies with the applicable standards.
The appliance must be tested with a full gas cylinder.
1. Make sure the safety valve is in the OFF position.
2. Prepare a soapy water solution by mixing one part liquid soap and one part water. The soapy water solution
can be applied with a spray bottle, brush or cloth to all gas connections. In case of a leak, soap bubbles will
appear.
3. Turn the gas supply ON.
4. In case of a leak, turn the gas supply OFF.
Tighten any leaking connections, then turn the gas supply ON and check again. If bubbles still appear, contact
your dealer or gas supplier. Connections to check are as follows: Cylinder valve/ regulator, Regulator/Hose,
Hose/Appliance gas inlet.