Descargar Imprimir esta página

Barmatic DICE 100 Manual Del Usuario página 10

Máquina de hielos

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 83
voir and refill it. Pour the sanitizer into the water reservoir
GB
to get a solution as in the point 12.
18. Allow the solution to circulate in the water system for 20
minutes and then set the switch to the OFF position.
19. To purge out the sanitizer solution and residue move the
switch to the "WASH" position (drain and refill) and allow
the water to circulate for 5 minutes and then move the
switch to the OFF position (drain). Repeat this operation
two more times to rinse thoroughly.
20. Return the panel to their position.
21. Set the switch to the ON position (position I) and discard
the first two ice production.
Maintenance
• Whenever you open up the appliance, check all the water
connections, the condition of the washers and hoses to avoid
leaks and to prevent breakages and flooding.
• Check the operation of the appliance regularly to prevent se-
rious accidents.
• If you see that the appliance is not working properly or that
there is a problem, stop using it, switch it off and contact the
supplier.
• All maintenance, installation and repair work must be car-
ried out by specialised and authorised technicians, or recom-
mended by the manufacturer.
Transportation and Storage
• Before storage, always make sure that the appliance has
been disconnected from the power supply and water connec-
tion or the water tap is closed.
• Store the appliance in a cool, clean and dry place.
• Never place heavy objects on the appliance as this could
damage it.
• Do not move the appliance while it is under operation. Dis-
connect the appliance from power supply when moving and
hold it at the bottom.
Troubleshooting
If the appliance does not function properly, please check the
below table for the solution. If you are still unable to solve the
problem, please contact the supplier/service provider.
270486, 270493
Problems
Possible cause
The
Appliance is disconnect-
appliance
ed from the mains.
does not
Curtain is not closed
work.
properly.
No water
Lack of water.
in tray
Inlet water valve blocked
Slab with
Cycle time not adjusted
ice is
properly.
empty or
too thick.
10
Possible solution
Plug in the appliance.
Check if there is no
ice and curtain moves
freely.
Check water supply.
Check and clean.
Adjust cycle time.
Difficult
Appliance not leveled
releasing
properly - tilted to back.
of slab
with ice
during
harvest.
Not uni-
Dirty or scaled dis-
form flow
tributor.
pattern at
evapora-
tor.
Unit run
Safety presostat opens.
and stops
alterna-
tively
itself.
270516
Problems
Possible cause
The
Appliance is disconnect-
appliance
ed from the mains.
does not
Appliance is switch OFF
work.
(rear).
Front switch in position
"0".
Compres-
Front switch on "WASH"
sor doeas
position.
not work.
No water
Lack of water.
in tray
Inlet water valve blocked
Not
Water level probe too
enough
low.
water to
Defective drain valve.
end cycle.
Shield splash leaks.
Water tray
Water level probe too
overflows.
high or scaled.
Slab with
Thickness probe badly
ice is
adjusted or scaled.
empty or
too thick.
Appliance not leveled
Difficult
releasing
properly - tilted to back.
of slab
with ice
during
harvest.
Not uni-
Dirty or scaled dis-
form flow
tributor.
pattern at
evapora-
tor.
Low ice
Dirty condenser.
produc-
tion.
Level appliance -
change position.
Perform descaling
procedure.
Remove and clean
distributor
Clean air condenser
(behind front grid).
Possible solution
Plug in the appliance.
Switch ON appliance.
Set on "ICE" position
(behind front panel).
Check water supply.
Check and clean.
Change probe
position.
Disamble and clean.
Check shield position.
Adjust or clean.
Adjust or clean.
Level appliance -
change position.
Perform descaling
procedure.
Remove and clean
distributor
Clean condenser.

Publicidad