PELIGRO
Conexiones eléctricas defectuosas llevadas a cabo por personal no calificado.
Riesgo de perder la vida debido a una descarga eléctrica.
CAUTION
Excessively high density fluids being handled.
Motor overload.
DANGER
Excessive pressure and temperature if the pump is operated with the closed suction
and/or discharge lines.
Explosion hazard.
Hot or toxic fluids leaking.
61
V7.101222
•
Asegúrese de que la instalación eléctrica sea siempre llevada a cabo por un
electricista entrenado y calificado.
•
Observe la regulación IEC 60364 y la norma EN 60079 para modelos a pruebas
de explosión.
•
Observe the information about fluid density in the data sheet.
•
Ensure the motor has sufficient power reserves.
•
Install suitable motor overload protection.
•
Never operate the pump with the Isolation valve(s) in the suction line and/or
discharge line closed.
•
Only start up the pump set with the discharge-side Isolation valve(s) slightly or
fully open.
•
Never operate the pump outside of its minimum stable continuous flow or in
excess of its maximum stable continuous flow.
Bomba Vertical de Turbina
VTP