9.7.2 Base menu instruction
Menu
Press "PROG" to enter
into base menu.
Working Mode
EN
Option
Press "+"(up) or "-"(down) to select;
Press "SET" to confirm.
Standard mode; O/C/S
(Open/Close/Stop).
O/S/C standard mode with automatic
closing function. When the gate opens, it will
automatically close after automatic closing
time. If a "close the gate" command is sent during
the automatic closing time waiting time, the
automatic closing function will be canceled.
Community mode (with automatic
closing function). When the gate opens, any gate
command will not be responded until it closes
automatically. If user sends gate command during
the closing process, then the gate will reopen. If a
gate command is sent during the automatic
closing waiting time, this waiting time will be
recalculated. If the gate is not closed completely
for more than ten consecutive times, the
automatic closing function will be canceled and
the gate will be closed by re-sending the gate
closing command. Note that in community mode,
the gate still has the automatic closing function in
case of meeting obstacles.
External three keys (open/close/stop)
Default/Attention
Standard
mode; O/C/S
(Open/Close/Stop).