9.7.4 Advanced menu instruction
Menu
Long press "PROG" 2 seconds
to enter into base menu.
Travel time adjustment
Photo Sensor
Electric Lock
Reverse push lock
Option
Press "+"(up) or "-"(down) to select;
Press "SET" to confirm.
Time of of gate1
Time of of gate2
Time fine tuning of of gate 1
Time fine tuning of of gate 2
N/C; photo sensor normally is on.(Default)
N/O; photo sensor normally off.
Electric lock normally is on. (Default)
Electric lock normally is off.
Reverse push lock
Reverse push lock
(When the electric lock is started, M1 will run for a
distance in the direction of the door to prevent the
electric lock from getting stuck and unable to be
opened.)
EN
mode off
mode on
Default/Attention
After automatic learning, if the
stroke is not ideal, it can be
adjusted manually. The shorter
the time under the resistance
limit,
the
farther
deceleration distance of the
door. And in the Hall limit, the
shorter the time, the shorter
the door travel.
N/O; photo sensor
normally on.
Electric lock normally
on.
Reverse push lock
mode off
the