Connecting the pulse generator:
 Attach the pulse generator in the opening
located on the bottom of the index and swing it
into the sealable plug connector on the right-
hand side of the index. Now secure it with the
enclosed rivet and seal (for this you will need a
pair of sealing pliers or a similar tool).
 Pull the locking pin provided with a snap
mechanism out of its guide (only for IN-Z61).
 Then connect the plug at the end of the prefabricated cable in the
designated opening on the bottom of the pulse generator.
 Secure the plug by re-inserting the locking pin into its guide (only for IN-
Z61).
 Assign the terminals in accordance with the pin assignment on the pulse
generator.
 IN-Z61, IN-Z62, IN-Z63, IN-Z64 and IN-Z65 can be retrofitted onto the Z6
index at any time without breaking the metrological seal.
6. RFID passive tag
WARNUNG!
The following conditions apply to meters marked with  and fitted
with an RFID passive tag:
 Under standard EN 60079-14, they must not be used in an
environment with high electromagnetic fields with an effective
value of over 1 A/m or 3 V/m.
 The RFID devices required for reading must be certified
separately for the appropriate explosion-hazard areas or may
only be used in safe areas.
 The transmission rating of the RFID readers must not exceed
the maximum limits set out in EN 60079-14.
16
73020212j