The generator is fitted with an overload cutout. This shuts down the sockets (3). You can restart the
sockets by reset the circuit breaker (6).
Important!
If this happens, reduce the electric power you are taking from the generator or remove any defective
connected appliances.
Important!
Defective overload cut-outs must be replaced only by overload cut-outs of identical design and with the
same performance data. If repairs are necessary, please contact your customer service centre.
3.5.
Cleaning and maintenance
a)
Switch off the generator and pull the spark plug boot from the spark plug before doing any cleaning
and maintenance work on the equipment.
b)
Use only non-corrosive cleaners to clean the surface.
c)
After cleaning the device, all parts should be dried completely before using it again.
d)
Store the unit in a dry, cool place, free from moisture and direct exposure to sunlight.
e)
Do not spray the device with a water jet or submerge it in water.
f)
Do not allow water to get inside the device through vents in the housing of the device.
g)
Clean the vents with a brush and compressed air.
h)
The device must be regularly inspected to check its technical efficiency and spot any damage.
i)
Use a soft, damp cloth for cleaning.
j)
Do not use sharp and/or metal objects for cleaning (e.g. a wire brush or a metal spatula) because they
may damage the surface material of the appliance.
k)
Do not clean the device with an acidic substance, agents of medical purposes, thinners, fuel, oils or
other chemical substances because it may damage the device.
Air filter (B10-11)
Clean the air filter at regular intervals and replace it if necessary.
Remove fixing bolt on the air filter cover (B10).
Remove the filter elements (B11).
Important!
Do not use abrasive cleaning agents or petrol to clean the elements.
Clean the elements by tapping them on a flat surface. In cases of stubborn dirt first clean with soapy
water, and then rinse with clear water and air dry.
Assemble in reverse order.
Spark plug (B9)
Check the spark plug (item 21) for dirt and grime after 50 hours of operation and if necessary clean with a
copper wire brush. Thereafter service the spark plug after every 50 hours of operation.
Pull off the spark plug boot with a twist.
Remove the spark plug with the supplied spark plug wrench (22).
Assemble in reverse order.
Changing the oil and checking the oil level (B12-B14)
The motor oil is best changed when the Engine is at working temperature.
Only use motor oil SAE - 15W40 / (<0 OC) [SAE - 5W30].
Fill up Oil. (B12)
Open the oil filler plug by screw it off (8).
Add engine oil with an oil filling jug.
Screw the Oil filler plug back.
Checking Oil level. (B13)
Place the generator on a slightly inclined surface so that the dip stick is at proper position.
Screw off the Oil Filler plug and wipe off any oil on the dip stick.
Put the oil dip stick back without screw into the Oil filler.