BATTERY COLD CRANKING AMPERES (CCA)
Excessive available CCA can damage starters. CCA rating is the current a battery can supply at '0' degree F (-18C) [See TMC RP 109A]. Following
are Maximum Battery CCA Recommendations for Delco Remy Starters by Serie
37MT 12V 1875 CCA
40MT 12V 2500 CCA
24V 900 CCA
*An Over Crank Protection (OCP) motor should be used whenever these CCA recomendations are exceeded.
ELECTRICAL INSTALLATION INSTRUCTIONS (See figures 2 & 3, page 2)
REVIEW DESCRIPTIONS IN THE TABLE BELOW TO DETERMINE THE FEATURES OF THIS STARTER VS THE ONE BEING
REPLACED. THE SET OF INSTRUCTIONS TO FOLLOW MUST BE SELECTED BASED ON FEATURES OF BOTH STARTERS.
NNOTEE THIS STARTER MAY ALSO BE VERY DIFFERENT IN SIZE AND APPEARANCE THAN THE ONE BEING REPLACED.
New Starter
A
Magnetic Switch (Relay) not attached to starter
B
Magnetic Switch (Relay) attached to starter
C
Magnetic Switch (Relay) attached to starter
A
Starter and starter being replaced do not have an attached magnetic switch (relay).
1.
Connect lead to solenoid switch terminal as removed from old starter solenoid.
2.
Connect positive (+) cable to solenoid battery (+) terminal as removed from old starter.
3.
Connect ground (-) cable to insulated/ground terminal on starters that have one, as removed from old starter.
B
Starter and starter being replaced both have an attached magnetic switch (relay).
1.
Connect lead to switch terminal of magnetic switch (relay) as removed from old starter.
2.
Connect positive (+) cable to solenoid battery (+) terminal as removed from old starter.
3.
Connect ground (-) cable to insulated/ground terminal on starters that have one, as removed from old starter.
C
Starter with attached magnetic switch (relay) replacing starter without an attached magnetic switch (relay).
1.
If this starter has a lead and connector assembly attached to the switch terminal of the magnetic switch (relay), remove it and
dispose. Go to step 2.
2.
Connect lead removed from the old solenoid switch terminal to the switch terminal of the magnetic switch (relay) on the new
starter.
Note!
The separately mounted magnetic switch (relay) will remain in the circuit and continue to function.
3.
Connect positive (+) cable to solenoid battery (+) terminal as removed from old starter.
Connect ground (-) cable to insulated/ground terminal on starters that have one, as removed from old starter. Delco Remy
strongly recommends the use of a ground cable.
BATTERY (+) TERMINAL
27-34 Nm (20-25 lb ft)
GROUND TERMINAL
1.9-2.4 Nm (17-21 lb in)
SOLENOID GROUND CABLE
INSULATED/ GROUND TERMINAL
[Connect to vehicle ground (-)]
27-34 Nm (20-25 lb ft)
OVER CRANK PROTECTION
(OCP) CONNECTION (Optional)
NOTICE
- Only licensed Delco Remy products and component parts should be used, and the use of other parts or modifications not approved by PHINIA
will void all applicable warranties. The failure to carefully follow these Instructions, set forth herein, will void all applicable warranties. DELCO REMY is a
registered trademark of General Motors LLC, licensed to PHINIA Technologies Inc.
© 2023 PHINIA Inc. All rights reserved
41MT 12V 1875 CCA
24V 1250 CCA
24V 900 CCA
42MT 12V 2500 CCA
24V 1250 CCA
Old Starter
Magnetic Switch (Relay) not attached
Magnetic Switch (Relay) attached
Magnetic Switch (Relay) not attached
SOLENOID MOUNTING SCREWS (3)
14.1-21.4 Nm (10-16 lb ft)
SOLENOID SWITCH
SWITCH TERMINAL
1.8-3.4 Nm (16-30 lb in)
MOUNTING FLANGE
HOLES (3)
INSUFFICIENT CLEARANCE
FOR SOCKET WRENCH
NOTICE! If Hex Head Size is too small,
a hardened washer or special 12-Point Head
FIGURE 2
Cap Screw (Grade 5)
2
50MT 12V 3600 CCA
24V 1800 CCA
FIGURE
Install
Yes
Yes
Yes
1
use