SOLENOID GROUND CABLE
INSULATED/ GROUND TERMINAL
[Connect to vehicle ground (-)]
27-34 Nm (20-25 lb ft)
OCP CONNECTION
(Optional, See figure 2)
Technical support: USA 800 372 0222, Mexico 01 800 000 7378, Brazil 0800 703 3526, South America 55 11 3183 0384
or visit delcoremy.com
NOTICE
- Only licensed Delco Remy products and component parts should be used, and the use of other parts or modifications not approved by PHINIA
will void all applicable warranties. The failure to carefully follow these Instructions, set forth herein, will void all applicable warranties. DELCO REMY is a
registered trademark of General Motors LLC, licensed to PHINIA Technologies Inc.
© 2023 PHINIA Inc. All rights reserved
BATTERY (+) TERMINAL
27-34 Nm (20-25 lb ft)
GROUND TERMINAL
1.9-2.4 Nm (17-21 lb in)
SWITCH TERMINAL
1.9-2.4 Nm (17-21 lb in)
MAGNETIC SWITCH (RELAY)
SOLENOID / IMS
MOUNTING SCREWS (3)
14.1-21.4 Nm (10-16 lb ft)
MOUNTING FLANGE
FIGURE 3
3
HOLES (3)