2.2 USING THE TOOL MANAGER SOFTWARE
2.2.8 CONFIGURING PARAMETERS OF THE TOOL
(5) Set a Snug Point
The snug point is used as a reference point to divide angle measurements into the angle before snug
and the angle after snug.
The snug point can be set from three methods: [When Pulsing Starts], [Snug Torque], and [Select
From Graph].
Torque
█ When Pulsing Starts
The point in time when the tool started pulsing is regarded as a snug point. It is set just by selecting
the item.
█ Snug Torque
• The point in time when tightening reached the set torque is regarded as a snug point.
• After selecting the item of [Snug Torque], enter the value of [Detection Threshold].
█ Select From Graph
• Select a desired snug point from the torque waveform data.
• A rise in torque to a 1° increase in tightening angle at the selected point (a slope in graph) is the
threshold for determining the snug.
Note
• If there is a steeper slope in graph before the selected point, that point will be judged to be the
snug point.
• Select the item of [Select From Graph], and click [Select Snug Point].
The graph window opens.
EN
Select From Graph
Snug Torque
When Pulsing Starts
Free Run
Pulsing
- 53 -
Continued to the next page
Angle