2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Ignore Rundown Result Before Snug
[Functional overview]
When this function is ON, if work is interrupted by trigger-off before the snug point, the
history log for that will not be recorded.
From the "Snug Point" parameter, set the method for determining the snug point.
[Default value]
OFF
[Setting value]
ON, OFF
Snug Torque Detection Delay
[Functional overview]
The tool will not shut off even if a load is generated on the way that exceeds the set
shut-off torque before the set time has passed since work started.
[Default value]
*0.0 s
[Setting value]
*0.0 s to 3.0 s
Buzzer
[Functional overview]
This is a condition option for sounding a buzzer when work is complete.
OFF:
Buzzer OK:
Buzzer NOK:
[Default value]
OFF
[Setting value]
OFF, Buzzer OK, Buzzer NOK
Entering the value with (*) will disable the function.
EN
A buzzer is not set off after work is complete.
After work is complete, a buzzer is set off when the result is OK.
After work is complete, a buzzer is set off when the result is NOK.
- 67 -