2.2 USING THE TOOL MANAGER SOFTWARE
2.2.10 SETTING OPTIONS FOR THE TOOL
3
Set the Maintenance Interval Alarm (Pulse Time).
The Maintenance Interval Alarm (Pulse Time) can be set from the tool info window.
Maintenance Interval Alarm (Pulse Time)
[Functional overview]
This is an alarm that counts the pulsing time that has been accumulated since the
tool started to be used, and reminds you of maintenance timing.
When you have 1 hour or less to go before the set time, the control panel display
will give you a warning.
If the set time is reached, the control panel display will remind you of that, and the
tool's motor will be locked (stopped).
Initializing the tool will reset the accumulated pulsing time, and also unlock the
tool's motor.
CAUTION
• When the tool is initialized, the other parameters will also return to the factory
defaults.
If you initialize the tool, be sure to reconfigure parameters before using it
again.
Warning display (changing every 0.5 seconds):
Setting value (1 to 99) → -1 → Operation mode (A or C)
Stop display (changing every 0.5 seconds):
Setting value (1 to 99) → 0
[Default value]
*0 hours
[Setting value]
*0 hours to 99 hours
Entering the value with (*) will disable the function.
1. Enter time it takes to sound an alarm, in the input field (①) of [Maintenance
Interval Alarm (Pulse Time)].
2. When you select [Set Interval Alarm] (②), the alarm will be set to the tool.
EN
①
●
- 70 -
②
●
Continued to the next page