6. Commissioning
The product is supplied in so-called simple operation mode for stand-alone operation (SA).
This document describes the commissioning process for stand-alone operation only.
Stand-alone operation is permanently switched off as soon as the product is configured for the
first time using the MDU 110 mobile data transfer unit or the Dialock Manager app. After that,
reactivating this operation mode is only possible after a complete reset ( 10.2 Complete reset,
page 37).
When using the product with Dialock software applications or the Dialock Manager app,
the commissioning process is described in the respective instructions.
The commissioning process begins automatically once the batteries have been inserted.
For safety reasons, commissioning can only take place within 5 seconds of the batteries
being inserted.
•
Read through the steps carefully before commissioning.
•
Ensure both master keys (the "green" programming key card and "red" clearing key
card) are to hand before commissioning.
•
Perform the work operations quickly and without interruptions.
If the commissioning time window is exceeded:
•
Remove the batteries.
•
Restart the commissioning process.
Recommendation: Before commissioning, carry out a firmware update with the
My Dialock Manager app or the MDU 110 mobile data transfer unit to ensure that
the current Dialock firmware is on the terminal.
To do this, contact our Dialock service at www.hafele.com.
30