10.2
Complete reset
A complete reset will reset the locker lock to its factory settings. All data will be deleted.
The locker lock must then be reconfigured ( 6. Commissioning, page 30).
A complete reset is required in the following cases:
•
Complete erasing of all data (e.g. in the event of return to stocks / warehouse).
•
Resetting of software operation to stand-alone operation (SA).
Prerequisites:
1. Remove the lock case from the installation
housing. Place the push-button on the contacts
in the lock case.
► Press push-button.
► The signal tone sounds briefly.
► Red and green LEDs illuminate.
Push-button (910.53.311)
2. Press and hold the push-button for at least 3
seconds.
A factory reset is performed.
► Red and green LED flash 5x/sec..
► Acoustic signal is heard.
► The factory settings are restored.
► Remove the push-button.
► The locker lock switches to commissioning
3. Insert the lock case into the installation
housing. Install LL 300.
1 s
mode (6. Commissioning, page 30).
en
5 x/s
37