5.
Worker's system parameter list (point
Parameter
Function
Operate
P-01
mode
Sensor
P-02
switch
Cutting line 3
P-03
Suction
P-04
Back pulley
P-05
wheel
Foot press-
P-06
er
Start speed
P-07
mode
Needle
P-08
position
Machine
P-09
stop auto
foot press-
er lifting
Suction by
P-10
hand
Start sew-
P-11
ing speed
Max speed 5000
P-12
The degree
P-13
of the work-
ing LED
light
The back-
P-14
light degree
Semi-auto
P-15
continue
sewing
Semi-auto
P-16
constant
sewing
Default
Adjustment
values
Range
0
0~1
1
0~1
0~3
3
0~3
0
0~2
3
0~3
1
0~1
0
0~1
0
0~1
1
0~1
4800
200-5500
200-5500
4
0~5
1
0~1
0
0~1
0
0~1
12
enter)
Description
0: Semi-automatic
1: Fully automatic
0: Closed
1: Open
0: Close
1: Before the cut line
2: After the cut line
3: Before and after the shear line
0: Closed
1: Before the inspiration
2: After the inspiration of
3: Before and after the inspiration
0: close
1: sewing in
2: after sewing
0: No lifting of the foot
1: Front lifting foot
2: After the lifting of the foot
3: Before and after the lifting of the foot
0: Automatic
1: Pedal
0: Upper pin position
1: A needle
0: Closed
1: Open
0: Closed
1: Open
0: Closed
1: Open
0: Closed
1: Open
0: Closed
1: Open