Front sensor sensitivi-
S17
ty degree
Back sensor sensitivi-
S18
ty degree
Front foot presser lift
S19
retaining time
Back foot presser lift
S20
start time
Foot presser protec-
S21
tion time
Release foot presser
S22
protection time
Continue feed cloth
S23
suction cutting line
Operate manual
S24
switch action
Safe switch choice
S25
The knife retaining
S26
time
Recover time
S27
Sensor mode (number
S28
choice)
Front sensor polarity
S29
Back sensor polarity
S30
Foot presser full pow-
S31
er time
Foot presser full
S32
power
Foot presser retaining
S33
power
Back cutting line sen-
S34
sor sensitivity degree
55%
20~175
55%
20~175
220
100-2000MS
0
0~2000MS
6
1~120S
20
20~800MS
0
0~1
1
0~1
3
0~3
35
1~1000MS
5
5~100S
2
1~2
0
0~1
0
0~1
180
10~990MS
100
20~100%
25
10~90%
55
5~99%
8
Confi gures the sensitivity degree of
the front sensor for different fabrics.
Adjusts the sensitivity degree of the
back sensor to adapt to different
fabrics.
Sets the duration for retaining the
front foot presser lift.
Determines the response time for
lifting the back foot presser.
Specifi es the protection time after
manually lifting the presser foot.
Sets the time for releasing the foot
presser.
Controls the continuous feed cloth
suction for cutting line.
0: close
1: open
Manages the manual switch action
during motor operation.
Selects the safety switch mode.
0: Off safety switch
1: Seam safety switch
2: Foot safety switch
3: open the safety switch
Determines the retaining time for the
cutting knife.
Sets the recovery time to jump back
to the main menu interface.
Chooses the sensor mode (1: single
or 2: double photo-eye).
Adjusts the front sensor polarity.
Sets the back sensor polarity.
Confi gures the full power time for the
foot presser.
Adjusts the full power output when
the foot starts moving.
Sets the retaining power for the foot
presser after lifting.
Determines the sensitivity degree for
the back cutting line sensor.