The minimum cable required for this charging device is 5*2.5mm square.
[ LB-13-3P 11kw]
The length shall not exceed 40 meters. If more than 40 meters, please choose 3*6 square
cable. Use at least C20 4P circuit breaker for a 11KW charger.
The minimum cable required for this charging device is 5*6mm square. The
[ LB-32-3P 22kw]
length shall not exceed 40 meters. If more than 40 meters, please choose 3*10 square
cable. Use at least C40 4P circuit breaker for a 22KW charger.
Check the local electrical codes regarding the need to install an external emergency shut-
off switch for the JATRHG charging station.
Due to the risk of electric shock, the electrical installation for
powering the charging station must always be performed by
qualified personnel and in accordance with the electrical
regulations in force in your country.
Failure to comply could result in electric shock, which could be fatal or cause
serious injuries.
Since the installation of the JATRHG charging station varies from one
user to another, the necessary electrical equipment (e.g., switches,
wiring, installation accessories) is not standardized and is
therefore not provided with the JATRHG charging station.
Installed on a pedestal stand JATRHG:
Use a screwdriver to fix the backplane on a stand with screws in bag 5.1;
fix the cable holder on the stand with screws in bag 5.3.
(www.jatrhg.com)
Installed on the wall
Risk of electrocution! The device must always be installed by qualified electricians
in accordance with local regulations.
1.
Drill holes according to the positions on the Mounting Plate (5).
2.
Secure the Mounting Plate to the wall.(using 5.1 x 6)
3.
Drill holes according to the positions on the gun holder plate (2).