Annex 3 : Maximum Peak Power Calculation - IMEON ENERGY IMEON 3.6 Guía De Montaje

Ocultar thumbs Ver también para IMEON 3.6:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Annex 3 : Maximum peak power calculation

Some devices will require a higher start-up power than the operating power. This specificity must be
considered.
Peak power = Equipment nominal power × start-up coefficient
See below some example of equipments showing difference between the operation power and the
minimum acceptable power for the inverter.
Equipment
FR
FR
EN
ES
To identify the exact power of your equipment, please consult the manufacturer datasheets on the
device manual.
Note: Calculations have been done for mono-phase devices.
IMEON 3.6 : Overload power capability at nominal voltage (AC
100
Manuel d'installation / Installation guide IMEON Inverter/ Guia de montaje – Rev C.12
IMEON INVERTER
Operating power
Electric oven
2 500 W
Television
300 W
Portable
900 W
grinder
Circular saw
1 100 W
Freezer
300 W
Single phase
1 500 W
compressor
Washing
3 000 W
machine
OUTPUT)
Start-up Coefficient
Maximum peak power
1
1
2,5
2,5
3,5
3,5
3,5
IMEON 9.12 : Overload power capability at nominal
voltage (AC OUTPUT)
2 500 W
300 W
2 250 W
2 750 W
1 050 W
5 250 W
10 500W