Descargar Imprimir esta página

Astralpool CEL-30 Manual De Instalación Y Mantenimiento página 6

Filtros diatomeas

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
• |f necessary, clean the cartridge with a water hose. If the filter is still dirty, it will
be necessary to clean it with suitable chemical cleaning products.
» Store the cartridge in a dry place and protect it from frost.
• Keep the filter in a bag to protect it from water and sunlight.
« It is also recommended that all the piping be emptied to avoid any damage caused
by frost.
14. TROUBLESHOOTING
CAUSE
SOLUTION —
Dirty cartridge
| Clean cartridge
|
: filtration
fl
|
i
|
|
ela filtration
flow
Blocked piping
| Check piping, valves
Pump motor rotates in the opposite direction | Invert rotation direction
Air entering pump
| Eliminate possible leaks
|
Half closed inlet suction
| Open inlet suction valves
Algae in the swimming pool
| incorrect quanlily of diatomaceous earth
| Saturated diatomaceous earth
| Clean cartridge
|
a
|
Dirty cartridge
Clean cartridge
Pressure gauge
oscillation
Rapid pressure
increase
Water not clean
enough
15. SAFETY WARNINGS
* Do not connect the system to the water mains, since the pressure may be very high
and exceed the maximum working pressure of the filter.
« Protect the filter from frost.
» Before handling the filter, ensure that the pump is switched off and that the filter
is not under pressure.
+ Lubricate the sealing rings with Vaseline before installing them.
+ ALWAYS purge the air from the filter before starting a cycle.
* When emptying the diatomaceous earth from the filter, check the RELEVANT
LEGISLATION, since it is not permitted to directly tip it into the drain system in
some countries.

Publicidad

loading

Este manual también es adecuado para:

Cel-40Cel-50Cel-70