DRAIN CONNECTION HEIGHT
The drain connection method depends on the height of the drain hose
connection.
IMPORTANT: Failure to connect the drain hose at a height of 18" with air
gap (not provided) OR to create a drain loop with a minimum height of
32" (81.3 cm) will result in improper draining of the dishwasher.
WATER SUPPLY REQUIREMENTS
Water pressure from the hot water supply line must be between
20-120 psi (138-862 kPa).
Water heater that is adjusted to a water temperature of 120°F to 150°F
(49°C to 65.5°C).
3/8
A
" min. diameter copper tubing water line extending at least 24"
(61 cm) from the rear wall, and routed to connect to the front left-hand
side of the dishwasher.
A hand shut-off valve in an accessible location, such as under the sink
(optional, but strongly recommended).
ELECTRICAL REQUIREMENTS
WARNING
10
IMPORTANT:
The dishwasher must be supplied with 120 volt, 60 Hz., and connected
to a dedicated, properly grounded branch circuit, protected by a 15 or
20 ampere circuit breaker or time delay fuse.
Maximum of two field wiring supply onductors (12 AWG Maximum)
plus one grounding conductor are permitted in the terminal box.
Use Only copper wire.
Wiring must be 2-wire with ground.
Use a UL Listed/CSA Approved metallic strain relief.
Be sure that the electrical connection and wire size are adequate and
in conformance with the National Electrical Code, ANSI/NFPA No.
70-latest edition and all local codes and ordinances.
If the electrical supply does not meet the above requirements, call a
licensed, qualified electrician be ore proceeding.
Electrical Shock Hazard
Installation and service must be performed by a
qualified in taller or service agency.
Always disconnect the power before servicing this unit.
This appliance must be properly grounded.
Failure to do so could result in death, fi e, or electrical
shock.