Instollotion
Instructions
CONNECTING AN ELECTRIC DRYER
(Skip for gos dryers ond if your dryer olreody
hos o power cord ottoched)
TOOLS YOU WILL NEED
OSlip-joint
pliers
0 Phillips screwdriver
0 Flat-blade
crewdriver
0 Level
MATERIALS YOU WILL NEED
04" dia. metal elbow
OGIoves
O3/4" strain relief
(UL recognized)
04" duct
clamps
(2) or
4" spring clamps (2)
0 Exhaust hood
0 Duct tape
0 Safetyglasses
)
O4" dia. metal duct
(recommended)
O4" dia., UL-listed
flexible metal duct (if
needed)
O Dryer power cord kit
(not provided with
dryer)
UL rated 120/240V,
30A with 3 or 4 prongs.
Identify the plug type
as per the house
receptacle
before
purchasing
line cord.
Before making the electrical
connection,
turn off
the circuit breaker(s) or remove the dryer's circuit
fuse(s) at the electrical
box. Be sure the dryer cord
is unplugged
from the wall. NEVER LEAVE THE
ACCESS COVER OFF THE TERMINAL
BLOCK.