ELECTRICAL CONNECTION
INFORMATION
FOR ELECTRIC DRYERS
For electrical
connections
using a
power
cord:
- Fire Hazard
Use a new UL-listed 240V :30amp dryer power supply
cord with closed ring terminals or spade terminals with
upturned ends.
Use a UL-listed strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining two supply wires to remaining two
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical
shock.
GROUNDING
INSTRUCTIONS
For a grounded,
cord-connected
dryer: This dryer
must be grounded.
In the event of a malfunction
or breakdown,
grounding
will reduce the risk
of electric shock by providing
a path of least
resistance for electric current. This dryer uses a
cord having an equipment-grounding
conductor
and a grounding
plug. The plug must be plugged
into an appropriate
outlet that is properly installed
and grounded
in accordance
with all local codes
and ordinances.
Improper connection of the
equipment-grounding
conductor
can result in a risk of electrical shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded. DO NOT modify the
plug on the power supply cord. If it will not fit the
outlet, have a proper outlet installed by a qualified
electrician.
SAVE THESE INSTRUCTIONS
ELECTRICAL CONNECTION
INFORMATION
FOR ELECTRIC DRYERS
For direct
wire connections:
- Fire Hazard
Use Z0 gauge copper wire.
Use a UL-Jisted strain relief.
Disconnect power before making electrical
connections.
Connect neutral wire (white or center wire) to center
terminal.
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining two supply wires to remaining two
terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical
shock.
GROUNDING
INSTRUCTIONS
For a permanently
connected
dryer: This
dryer must be connected
to a grounded
metal,
permanent
wiring system, or an equipment-
grounding
conductor
must be run with the circuit
conductors
and connected
to the equipment-
grounding
terminal
on the appliance.
Improper connection of the
equipment-grounding
conductor
can result in a risk of electrical shock. Check with a
qualified electrician, or service representative or
personnel, if you are in doubt as to whether the
appliance is properly grounded.
SAVE THESE INSTRUCTIONS