31 / EN
Follow the numbered steps below for a correct installation:
1.
Check that the voltage is appropriate for this appliance, you can verify the voltage on the
product data label.
2.
Install the water heater as close as possible to the electric current (charging center), with
the voltage that will be used, which must be accessible and must include a switch break
or QO breaker.
3.
As a safety measure, it is obligatory to install a thermo-magnetic circuit breaker according
to the model (see the electrical specifications table) independently of the main line, for
automatic deactivation in the case of an electrical fault or imbalance.
4.
Extend or lead the independent cables from the power supply through a conduit tube or
polyduct to the heater.
5.
Ensure and verify that the green physical ground cables are correctly connected to the
terminal at the charging center.
6.
Once the above has been completed, you can power the heater to start its operation.
Never omit the electric circuit's ground connection. (See Fig. 7). We recommend
connecting the green ground cables to a copper rod (copperweld).
7.
Grounding the appliance is obligatory, and the cables must be attached to the ground
connection.
FIG. 7
Grounding Diagram
Wire
Copper rod
(Copperwed), ½"
diameter x 1 m long