Descargar Imprimir esta página

Calorex ELEVA PRO 15 V2 Instructivo De Instalación, Operación Y Mantenimiento página 35

Calentador instantáneo eléctrico

Publicidad

Idiomas disponibles

Idiomas disponibles

35 / EN
Problem
The water temperature varies from
hot to cold during use.
The water is too hot.
The water has stopped flowing.
There is no hot water with the
open.
Possible Causes
The water pressure is below the minimum
level.
There is not enough water flow entering
the heater.
The ambient temperature has increased
or the temperature setting is too high.
The voltage is lower than 240 volts.
The tap water temperature is too high.
Power failure or faulty wiring.
Blockage in the tubes or pipes.
There is no water supply.
Power failure or faulty wiring.
activate the resistance (4 L/min).
Solutions
Increase the water flow.
The water flow increases.
Select a lower temperature value.
This heater is designed to operate at 240 volts. A
lower voltage prevents the heater from operating
correctly.
Check if the flow is too low, the temperature
adjustment is too high, or if there is an internal fault. If
the problem persists, contact a qualified electrician.
Check the power supply and the breaker. If the
problem persists, contact a qualified electrician.
Check that the water supply valve is completely open
and there are no obstructions in the supply line.
Check the power supply and the breaker.
Increase the water flow. Clean the filter screen at the
unit's water inlet.

Publicidad