TROUBLESHOOTING
POINTS
PROBLEM
Engine is running, 10ut n o
AC output is available.
Engine runs good at no-load but "bogs
down"when loads are connected
Engine will not start;or starts
and runs rough.
Engine shuts down dunng operation
Engine lacks power.
Engine "hunts" or faltera.
CAUSE
1. One of the circuitbreakers is open.
2. Fault in generator.
3. Poor connectionor defective
cord set.
4. Connected device is bad.
1.
2.
3.
4.
1.
2.
3.
4.
5.
.
7.
8.
9.
10.
11.
CORRECTION
1. Reset circuitbreaker.
2. Contact Sears Service DepadmenL
3. Check and repair.
4.
Short circuitin a connected load.
1.
Engine speed istoo slow.
2.
Generator is overloaded.
3.
Shoded generatorcircuit.
4,
Run/Stop Switchset to STOP.
1.
Dirty air cleaner
2.
Out of gasoline.
3.
Stale gasoline.
4.
Spark plug wire not connected
5.
to spark plug.
Bad spark plug.
6.
Water in gasoline.
7.
Overchoking.
8.
Excessivelyrichfuel mixture.
9.
Intake valve stuckopen or dosed.
10.
Engine has lost compression.
11.
12. Intake valve stuck opan or closed.
12.
13. Engine compressionlost.
13.
14. Failed battery.
14.
1.
Out of gasoline.
1.
2.
Low oil level.
2.
1. Load is too high.
1.
2. Dirtyair filter.
2.
1. Choke is opened too soon.
1,
2. Carburetoris runningtoo rich
2.
or too lean.
13
Connect another device that is
in good condition.
Disconnectshorted electrical load.
Contact Sears Service Department.
See "Don't Ovedoad the Generator
on Page 6.
Contact Sears Service Department.
Set switch to RUN.
Clean or replace air cleaner.
Fill fuel tank.
Drain gas tank; fillwith fresh fuel.
Connect wire to spark plug.
Replace spark plug.
Drain gas tank; till with fresh fuel.
Open choke fully and crank engine.
Contact Sears Service Department.
Contact Sears Service Department.
Contact Sears Service Department.
Contact Sears Service Department.
Contact Sears Service Department.
Replace battery.
Fill fuel tank.
Fill crankcase to properlevel.
See "Don't Overload the Generator"
on Page 6.
Replace air filter.
Move choke to halfway positionuntil
engine runs smoothly.
Contact Sears Service Department.