MAINTENANCE
Performance
Data Sheet
Models Number 5231JA2002A-S
Use with replacementcartridge 5231JA2002A
This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for water leaving the system as specified in
NSF/ANSI 42.
System tested and certified by NSF International against NSF/ANSI Standard 42 for
the reduction of Chlorine Taste and Odor and Nominal Particulate Class III.
Capacity:
500 ga[ (1,892
L)
Substance
Nominal Particulate
Class I Particle size:
>0,5 to < 1 um
Chlor ne taste and
odor Class Ill
Average
hfluent
Concentration
24,333
19
mnfluentChallenge
Concentration. Units apply
to each row
At least 10,000 partic]es/ml
2.0 mg/L ± 10%
Average
Product Water
Concentration
915
0.07
NSF % reduction req,
Average %
or Max. permissible
Reduction
product water
concentration
96
> 85%
96.4
_>50%
Note that while
the testing
was performed
under standard
laboratory
conditions,
actual
performance
may vary.
Application
Guidelines/Water
Supply Parameters
Service Flow
05
gpm (189 Ipm)
20 and 120 psi
Wafer Pressure
(140 and 830
kPa)
36 °F - 100 °F
Water Temperature
(0.6 °C - 37.8 °C)
r A
WARNING
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
, Systems must be installed and operated
in accordance with manufacturer's
recommended procedures and guidelines.
Warranty: See Warranty Card for Details.
For a replacement
cartridge or for service
contact your local dealer.
You can also visit our website; wwwJg,com
or catt 1-877-714-7486.
r-Z_
CAUTION
To reduce the risk of property damage due to
water leakage:
• Read and follow. Use instructions before
installation and use of this system.
, Install on COLD water lines only.
, Comply with all state and local plumbing
codes.
Install a pressure limiting device and water
hammer arrester for inlet water pressures
exceeding 80 psi (552 kPa). Refer to
Uniform Plumbing Code, Sections 608.2
and 609.10).
• Never install or operate where inlet water
pressure may exceed 125 psi (862 kPa).
• Protect filter from freezing. Remove filter in
temperatures below 33°F (0.6°C).
, Replace cartridge at specified service
interval. Cartridge MUST be replaced at
least every 12 months.
Manufactured
for LG® Electronics by:
CUNO tncorporateda
3M Company 400
Research Parkway Meriden, CT 06450 U.S.A.
Telephone: 203-237-5541
Fax: 203-238-8701