Descargar Imprimir esta página

Siemens EQ500 Integral TQ517R03 Manual De Usuario página 64

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 264
en Troubleshooting
Fault
No milk intake by the
milk system.
Milk froth is too cold.
Appliance is not dis-
pensing hot water.
Milk system cannot be
assembled or disas-
sembled.
Appliance is not dis-
pensing drinks.
There is dripping wa-
ter on the inner floor
of the appliance.
Brewing unit cannot
be removed.
Appliance cannot be
operated.
Change displays.
Grinder won't start.
64
Cause and troubleshooting
Order for connecting the milk container and milk sys-
tem is wrong.
First insert the milk system into the outlet and then
the milk container.
Milk tube not immersed in milk.
Use more milk.
Check whether the milk tube is immersed in the
milk.
Milk is too cold.
Use lukewarm milk.
Milk system is soiled.
Clean the milk system in the dishwasher.
Order of assembly is wrong.
First connect the milk system and then the milk
container. When disassembling, you must first re-
move the milk container and then the milk system.
Air is in the water filter.
Immerse the water filter in water with the opening
1.
facing upwards until no more air bubbles escape.
Reinsert the filter.
2.
→ "Inserting and activating the water filter", Page 49
Firmly press the water filter straight down into the
tank connection.
Residues of limescale remover are blocking the water
tank.
Remove the water tank.
1.
Clean the water tank thoroughly.
2.
Drip tray was removed too soon.
Wait a few seconds after the last drink was dis-
pensed before removing the drip tray.
Brewing unit is not in the removal position.
Switch the appliance back on.
Appliance is in demo mode.
Remove the water tank and fill with fresh cold wa-
1.
ter.
Reinsert the water tank.
2.
Appliance is too hot.
Disconnect the appliance from the mains.
1.
Wait 1 hour so the appliance can cool down.
2.

Publicidad

loading

Este manual también es adecuado para:

Eq500 classic tp515r02Eq500 classic tp511r09