7.6.14. Boost mode
Boost mode:
- Sets the production setpoint up to 125%, for a fixed period.
- Can be manually stopped at any time.
- Can be used when chlorine is needed.
I
Boost mode cannot replace a conventional shock treatment in the case of water not fit for bathing.
If the Boost mode is restarted manually while it is already running, the Boost mode resets for the duration displayed.
It is impossible to start Boost mode if an alarm has been triggered. After having resolved and dismissed this alarm,
wait a few moments in order to be able to activate the Boost mode.
When the Boost mode is manually terminated or stopped, production continues according to the initial setpoint.
Boost mode continues after powering off the electronics unit.
Operation with a cover sensor:
It is impossible to start Boost mode when the cover is closed.
If the cover closes with Boost mode activated, Boost mode stops automatically.
Possible
Menu
settings
12 hrs
24 hrs
7.6.15. Probe calibration: important advance information
The original pH probe provided is already calibrated. It is, therefore, not necessary to carry out calibration of the
pH probe when putting the equipment into service for the first time.
I
However, it is imperative to calibrate the pH probe at the beginning of each season when returning to service,
and after each probe replacement.
7.6.16. Calibrating the pH probe
1) Open the pH 7 and pH 10 calibration solutions (use only single-use calibration solutions).
2) Turn off the filtration (and therefore the electronics unit).
3) If the probe is already installed:
a) Remove the probe from the probe holder, without disconnecting it.
b) Remove the probe holder nut and replace it with the stopper provided.
If the probe is not already installed:
Connect the probe to the electronics unit.
4) Turn on the electronics unit.
5)
6) Navigate through the menus following the below instructions:
Default
Switching on
setting
Automatic as soon as
24 hrs
the time is set.
On LED (special display variants)
Switching off
Press
.
14