7.6.19. Bluetooth communication
Menu
Setting
When updating the software of the electronics unit via Bluetooth, the 2 LEDs (red and green) flash alternately and
the % of charge is displayed.
7.6.20. Auxiliary menu (UV lamp)
Menu
Allows you to set the percentage of time the UV lamp
is on in relation to the total filtration time of the
previous day. *
Allows you to set the percentage of time electrolysis is
on in relation to the total filtration time of the previous
day. *
Setting of a waiting time between the switching on of
the UV lamp and the start of electrolysis**.
Total
Reset
*
UV ratio at 60% = 60% of filtration time, i.e. 12 hours of UV at the beginning of the cycle.
Electrolysis ratio at 50% = 50% of the filtration time, i.e. 10 hours of electrolysis at the end of the cycle.
Comments:
The sum of the two cannot be less than 100%
The electrolysis time cannot be less than 4 hours per day. It is used to regulate the chlorine rate in your pool.
The operating times may overlap or be 100% identical
**Adjustable only in 100% synchronous mode (UV Ratio = Electrolysis Ratio = 100%), otherwise they are
automatically shifted.
Activation/deactivation
Mode
Bluetooth communication.
Detection of connectible
devices near the electronics
unit (within 60 seconds).
Pairing
Networking
electronics
connected devices.
Deletion
Reset
connecting the electronics unit
to the connected devices.
Operating time of the UV lamp
Reset/change of UV bulb
Function
of
of
the
unit
and
of
the
network
Possible settings
ON
OFF
-
Settings
From 0 to
100%, in
increments of
1.
From 0 to
100%, in
increments of
1.
From 1 to 60
min
in increments
of 10
0 to 13,000 h
Default setting
ON
Default setting
100%
100%
1 min
16