Descargar Imprimir esta página

Craftsman 82312 Manual Del Usuario página 9

Ocultar thumbs Ver también para 82312:

Publicidad

Idiomas disponibles

Idiomas disponibles

Notes:
Accuracy
specifications
consist oftwo elements:
• (% reading)
- This i sthe accuracy
ofthe measurement
circuit.
• (+digits) - This isthe accuracy
ofthe analog todigital
converter.
Accuracy
isstated at65°F t o83°F ( 18°C t o28°C) and less t han
75% RH.
Diode T est
Continuity Check
Input Impedance
AC Bandwidth
Display
Overrange
indication
Polarity
Measurement
Rate
Low Battery Indication
Battery
Fuses
Operating
Temperature
Storage
Temperature
Operating
Humidity
Storage
Humidity
Operating
Altitude
Weight
Size
Bias voltage: 2.3VDC
Audible signal will sound if the
resistance is less than 100£-._
10MC2(VDC & VAC)
50 ! 60Hz
2000 count (0 to 1999) LCD
"1
" is displayed
Automatic (no indication for
positive); Minus (-) sign for negative
2 times per second, nominal
r_
"LI " is displayed if battery voltage
drops below operating voltage
One (1) 9V battery
mA range; 200mA/250V
fast blow
A range; 10A/250V fast blow,
ceramic
32°F to 122°F (0°C to 50°C)
-4°F to 140°F (-20°C to 60°C)
Max 70% up to 87°F (31°C)
decreasing
linearly to 50% at 122°F
(50°C)
< 80% RH
7000 ft. (2000 meters) maximum.
9.17 oz (260g) includes holster
5.8" x 2.9" x 1.6" (147 x 76 x 42mm)
includes holster
Approvals
CE, UL

Publicidad

loading