No.
Component
9
Connection to pump (1" male thread)
2.3
Function
The Hydrocontrol is an electronic pressure switch
with integrated dry running protection and back-
flow stopper. It serves to convert a surface pump
into a domestic water pump.
2.4
Functions of the pressure switch
Automatic operation of the pump
When a shut-off device in the pressure line is
opened, the pump is automatically switched on
by the pressure switch. When the shut-off device
is closed, the pressure switch switches off the
pump again once the maximum pump pressure is
reached.
Protection of the pump against dry running
The pressure switch is equipped with a safety de-
vice that switches off the pump in the event of a
lack of water.
The pump is switched off after approx. 45 s, sig-
nalled by the lighting up of the "Failure" LED.
Constant delivery rate and pressure
The pressure switch ensures a constant delivery
rate with constant pressure.
Functioning range of the pressure switch
ON pressure: approx. 1.8 bar
OFF pressure max.: 8.0 bar (or maximum pres-
sure of pump)
2.5
Intended use
The appliance is intended for private use in the
house and garden. It may only be operated within
the framework of the operating limits indicated in
the technical data.
The appliance is suitable for:
Conversion of a surface pump or submersible
pressure pump into a pump with automatic
switching (domestic water pump).
The appliance is suitable only for conveying the
following fluids:
Clean water
Rainwater
Chlorinated water (swimming pool water).
Any use not in accordance with this designated
use shall be regarded as misuse.
10
2.6
Possible misuse
The pump must not be operated continuously. It
is not suitable for conveying:
Drinking water
Salt water
Foodstuffs
Waste water
aggressive media, chemicals
corrosive, flammable, explosive or fuming flu-
ids
fluids that are hotter than 35 °C
water containing sand and abrasive fluids.
3 SAFETY INSTRUCTIONS
DANGER! Danger from contact with live
parts! A defect in the pump or the extension ca-
ble can result in serious injury!
Disconnect the connector plug from the
mains immediately.
Connect the device via an earth leakage cir-
cuit breaker with a rated leakage current of
< 30 mA.
WARNING! Risk of injury. Defective and
disabled safety and protective devices can result
in serious injury.
Have any defective safety and protective de-
vices repaired.
Never disable safety and protective devices.
CAUTION! Danger of injury from hot wa-
ter After extended use against the closed pres-
sure side (> 10 min.), the water in the pump can
become very hot and may escape uncontrolled!
Disconnect the pump from the mains supply
and allow the pump and water to cool down.
Check the water level on the suction side.
Check the leak-tightness of the lines.
Check the installation of the suction and
pressure lines.
Put the pump into operation again only after
all the faults have been remedied!
3.1
General safety warnings
This appliance can be used by children of 8
years and older and by persons with reduced
physical, sensory or mental capabilities, or
those lacking experience and knowledge, if
they are supervised or have been instructed
with regard to the safe use of the appliance
Safety instructions