Installation
and the ensuing risks. Children must not be
allowed to play with the appliance. Cleaning
and maintenance must not be carried out by
children without supervision.
■
People with very strong and complex restric-
tions may have needs that exceed the in-
structions described here.
■
Never lift, transport or affix the pump by the
mains cable. Do not pull the mains cable in
order to pull the mains plug out of the socket.
■
Unauthorised modifications or conversions to
the pump are prohibited. Repairs may only
be carried out by our customer service.
■
Disconnect the mains plug before working on
the device. Protect the mains plug against
moisture.
■
Only use the pump and extension cable if
they are in flawless technical condition. Dam-
aged appliances must not be operated.
■
Maintain a safe distance to persons or ani-
mals or switch off the pump if animals ap-
proach.
3.2
Electrical safety
■
The pump may not be operated while people
are in the pool or pond.
■
The mains voltage at your location must com-
ply with the information regarding mains volt-
age in the Technical Data. Do not use any
other supply voltage.
■
The appliance must only be operated on
electrical equipment in accordance with DIN/
VDE 0100, parts 737, 738 and 702. For fuse
protection, a circuit breaker of 10 A and an
earth leakage circuit breaker with a rated
leakage current of 10/30 mA must be in-
stalled.
■
Use only 3 x 1.5 mm
quality H07RN-F to DIN 57282/57245 with
splash-proof plug connector. Cable drums
must be completely unwound.
■
The power consumption of the connected
pump must not exceed 10 A, and its operat-
ing pressure must not be less than 1.8 bar or
more than 8 bar.
■
Always switch off the pump operated with the
pressure switch and pull the mains plug of
the connecting lead out of the plug socket be-
fore starting maintenance, service and repair
work or in the event of faults. Protect the
mains plug from moisture.
467363_g
2
extension leads of
4 INSTALLATION
IMPORTANT! Danger of damage to the
pump! If a pre-filter is not installed, solids can
enter the pump and cause damage.
■
Install a pre-filter in the suction line for safe
operation of the pressure switch.
NOTE The pressure switch can be installed
at any point in the pressure line.
The pressure switch must always be installed
vertically. If direct installation at the pump outlet
is not possible for space reasons, a suitable con-
nector must be used.
1. Install the pressure switch (1" male thread) to
the pressure line connection at the pump out-
let.
5 START-UP
NOTE The pump cannot be filled via the
pressure switch, as a check valve is installed in
front of the pump.
NOTE During commissioning, the pump
switches off automatically after approx. 10 s. The
"RESET" (8) button must then be pressed until
the pump starts to deliver water. If the "RESET"
button is released before the pump starts to deliv-
er water, the pump switches off again automati-
cally for safety reasons. Should the priming pro-
cess take longer than 2 minutes, fill the pump
and suction hose again, check the screw fittings
for leaks and repeat the process.
1. Fill pump and suction until they overflow.
2. Open a shut-off device (valve, spray nozzle,
water cock) in the pressure line.
3. Insert the plug of the mains cable into the
power socket. The pumps starts to operate.
4. Close the shut-off device in the pressure line
when water flows out of the line without bub-
bles. The pressure switch switches off the
pump automatically after approx. 15 s. The
appliance is ready for operation.
6 OPERATION
Commission the appliance as described.
The pressure switch is electronically controlled
and operates fully automatically after commis-
sioning.
11