Screen backlight
With the DC adapter, the backlight can be always on.
• Press the
(Backlight/Snooze) to adjust backlight brightness: high, low, or off.
Without the DC adapter, the backlight turns on temporarily.
• Press the
(Backlight/Snooze) to turn the backlight on for 15 seconds.
Low battery indicator
The low battery icon in the temperature and humidity segments (indoor/outdoor) indicates the need to replace the batteries
in the corresponding devices (weather station / outdoor sensor).
Factory reset
If you have issues with the operation of the weather station or the 7-in-1 outdoor sensor, resetting to factory settings will
help return them to their original state.
• Disconnect all power sources (batteries and DC adapter) from the weather station and reconnect them. The weather
station will return to factory settings.
• To reset the 7-in-1 outdoor sensor, press the RESET button (11) on the sensor body or reinstall the batteries.
Maintenance
Rain gauge cleaning
Clean every 3 months. Rotate the funnel counterclockwise and lift to access the rain gauge mechanism. Wipe with a damp
cloth to remove dirt, debris, and insects. For insect problems, lightly spray with insecticide.
Solar radiation sensor and solar panel cleaning
Clean every 3 months with a damp cloth.
Battery replacement
Replace every 1–2 years. In harsh environments, check every 3 months. Batteries may leak when used for too long.
When replacing batteries: Apply a corrosion inhibitor, available at most hardware stores, to the battery terminals.
In snowy conditions
Spray the top of the weather station with anti-icing silicone spray to prevent snow accumulation.