Descargar Imprimir esta página

Coelbo Speedbox 1010 MT Instrucciones De Instalacion Y Utilizacion página 13

Publicidad

Idiomas disponibles

Idiomas disponibles

SCREEN DISPLAY.
Being the unit in automatic mode (LED AUTO ON) by mean of the push-button p can be displayed several operation parameters.
Where:
Pset is the set pressure or target pressure in bar.
n
Pbar is the instantaneous lecture of pressure in bar.
n
Hz is the rotation frequency of the motor in Hz.
n
A is the instantaneous current consumption in A.
n
ºC is the module temperature in ºC.
n
P s e t
P b a r
EXPERT MENU. Special configuration, there is no need to adjust these values, they are factory set.
Using pq we can change the values and press ENTER for validation. Whenever we want to quit the configuration sequence
press MENU. After every ENTER it will appears automatically the different screens that constitute the configuration sequence.
P s e t
4 ,
P b a r
3 ,
E X P E R T
V .
X X
Q O
1 9
Q 1
- 1 9
Q 2
8
A C C E L E R .
1 0
D E C E L E R .
1 0
F R E Q .
8 K H z
All manuals and user guides at all-guides.com
4
, 0
P b a r
3
, 9
H z
To start the configuration secuence press MENU + ENTER during 3"
0
9
Press ENTER
PID parameter, factory set. For any doubt contact with the manufacturer.
ACELERATION. Using pq it can be adjusted the desaceleration. Rank 5-20 (Hz/s).
Press ENTER to confirm.
DECELERATION. Using pq it can be adjusted the desaceleration. Rank 5-20 (Hz/s).
Press ENTER to confirm.
COMMUTATION FREQUENCY
8KHz o 4KHz. Press ENTER to confirm.
For installations with submersible pumps or where the cable of the device to the pump
exceeds 20m, it is advisable to work in a commutation frequency of 4Khz.
A
3
, 9
º C
3 7
Using pq it can be adjusted the commutation frequency
-11-
9
, 8
2 0
+
ENTER
MENU
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER

Publicidad

loading