EI.ECTRICAL
CONNECTIONS
(cont.)
3. Power Cord and Strain Relief installation
a. Remove the wire cover (on the lower back of the
range) by removing two (2) screws using a 1/4" nut
driver_
Do not discard these screws,
\
Back of range
b. Remove the knockout ring (I3/8 ") located on bracket
directly below the terminal block. To remove the
knockout, use a pair of pliers to bend the knockout ring
away from the bracket and twist until ring is removed
Terminal
block
c. For power cord installations
only (see the next step
if using conduit), assemble the strain relief in the hole
Insert the power cord through the strain relief and
tighten Allow enough slack to easily attach the cord
terminals to the terminal block If tabs are present at
the end of the winged strain relief, they can be
removed for better fit
NOTE: Do not instal] the power cord without a
strain relief. The strain relief bracket should be
installed before reinstalling
the rear range wiring
cover.
Strain retlef
e
/
Power cord
Terminal block
/
Bracket
Skip to Step 4 or 5
d. For conduit installations only, purchase a squeeze
connector matching the diameter of your conduit and
assemble it in the hole Insert the conduit through the
squeeze connector and tighten_Af]ow enough slack to
easily attach the wires to the terminal block
NOTE' Do not install the conduit without a squeeze
connector. The squeeze connector should be installed
before reinstalling the rear range wiring cover°
Knockout
ring in
bracket
Knockout ring
removed
Squeeze
connector
Conduit
Bracket
SkiptoStep6or7