Operation
SWING Operation
1.
For each press of the button, air
flow direction on remote controller
displays as follows according to
different operation modes:
QUIET
COOL/DRY/FAN:
HEALTH
MODE
I FEEL
AIRFLOW
HEALTH
SLEEP
TURBO
HEAT:
AUTO:
SELF
EXTRA
CLEAN
FUNCTION
ECOSENSOR
TIME
TIME
CONFIRM
ON
OFF
CANCEL
Initial state
LOCK
LIGHT
RESET
2.
Left and right air flow direction
For each press of the button, air flow direction on remote control-
ler displays as follows :
Initial state
NOTE:
1. When humidity is high, condensate water might occur at air
outlet if all vertical louvers are adjusted to left or right.
2. It is not advisable to keep horizontal flap at downward posi-
tion for a long time in COOL or DRY mode, otherwise, con-
densate water might occur.
3. As cold air flows downward in COOL mode, adjusting air
flow horizontally will be much more helpful for a better air cir-
culation.
7
Up and down air flow direction
SELF-CLEAN Operation
Functional description:
The purpose of this function is to clean
the evaporator.
Entry and exit:
SELF
CLEAN
If this function is needed, please select
in the hOn APP.
Press SELF CLEAN button to enter this
function. The display will show "CL" on
QUIET
the panel of the indoor unit and on the
HEALTH
MODE
I FEEL
remote controller. Maximum running
AIRFLOW
HEALTH
SLEEP
TURBO
time in this function is no more than 21
minutes. This function will exit automat-
ically with the " Pi " sound twice, then
the unit return to original state. During
SELF CLEAN operation, pressing the
button repeatedly will not exit the pro-
SELF
EXTRA
CLEAN
FUNCTION
ECOSENSOR
cess. Press ON/OFF button to exit this
TIME
TIME
CONFIRM
ON
OFF
CANCEL
mode.
LOCK
LIGHT
RESET
NOTE:
1. This function is invalid in TIMER / SLEEP mode.
2. After this mode starts, the air volume may reduce, have no
airflow, or even cold airflow blowing.
3. It is normal if the unit makes some sound when the air
expands with heat and contracts with cold.
4. The "CL" display time may last differently on the remote
controller and panel.
5. If the outside ambient temperature is below zero, error
code "F25 "may be show up during self-cleaning operation,
which is normal protection, please turn off the power and
restart after 10 seconds.
6. The best condition to run this mode is temperature is
between 20ºC~27ºC , the humidity is between 35%~60%
indoors, and the temperature is between 25ºC~38ºC (cool-
ing season)outdoors.
7. It is hard for the air to frost if the air is too dry (humidity﹤
20%). The condensate water may increase if the humidity
of the air is too high (humidity﹥70%) .