ELECTRICAL CONNECTION
Important
The connection must be made by authori-
sed, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
230V/1N.
Caution - warning
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
2 - Pull off the knob (B).
3 - Undo the screws (C) and remove the con-
trol panel (D).
4 - Connect the circuit-breaker (A) to the ter-
minal board (E) of the appliance as shown in
the diagram and in the electrical system dia-
WATER CONNECTION
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
IT
tap (A), to allow the water supply to be cut off when
necessary. Easily accessible filters must be fitted
downstream of the tap.
GB
Caution - warning
DE
The appliance must be supplied with drinking
water having the characteristics shown in the
table.
FR
Description
ES
Pressure
pH
Conductivity
Hardness
Salt and metallic ion con-
tent
Chlorides
Sulphates
Iron
Copper
Manganese
English
Value
200÷450 kPa (2÷ 4,5 bar)
7÷7.5
< 200 mS/cm
9÷13°f (5÷7°d, 6.3÷8.8°e,
90÷125 ppm)
< 30 mg/l
< 40 mg/l
< 0,1 mg/l
< 0.05 mg/l
< 0,05 mg/l
- 14 -
A
B
C
C D
gram at the back of the manual. Use a cable
with at least H05RN-F characteristics.
Important
When connecting, take care to connect the
neutral and earth lines.
5 - Replace the control panel (D) on completion of
the operation.
A
E
IDM-39611301500.tif
IDM-39610900800.tif