Attention: As indicated in the connection diagram, the master unit, to be confi gured as such, must not have other devices
connected in the C1 and C2 terminal blocks.
Attention: It is necessary to adhere to the connection between the S1-C1 and S2-C2 signals to avoid causing damage to the
EN
electronic device.
Confi guration of master product: slave
Check that the master unit doesn't have other devices connected in the terminal blocks (C1 and C2), then turn it on. After
the fi rst 10 seconds during which the red LED will remain steady, the product will emit two alternating white and red light
pulses and will be confi gured automatically as MASTER.Only once the product has been identifi ed as main MASTER unit it
is possible to start confi guring the SLAVE1.
Do not send any command from remote to the slave units.
Make sure the MASTER unit starts working before turning on the next (SLAVE) unit by means of switch "0/1" in order to give
the MASTER unit time to confi gure the SLAVE units in the desired sequence.
Turn on the SLAVE unit in sequence with switch 0/1, as explained below.
Each unit must only be turned on after the previous unit has effectively started working:
1. Master Unit
2. Slave 1 with operation opposite to Master
3. Slave 2 with operation same as Master
4. Slave 3 with operation opposite to Master
Attention: If the product is not confi gured correctly (MASTER or SLAVE) the RESET function can be used, which resets the
product to factory conditions. This procedure is explained in the remote control PRODUCT RESET.
3) CONCLUSION OF THE ASSEMBLY
Having done the connection, put the terminal block and the cables back in their housing. Insert the ceramic exchanger (7)
with the relative fi lters (8), positioning it half way along the integrated tube (6) as shown in the below image:
Snap the main unit (3), together with the damper components (2) and front embellisher (1) already mounted on it, into the
wall attachment (4i) until all the teeth are fastened.
Make sure you install the main unit on the wall with the switches at the top left.
29